MODEL SELECTION |
To select a Gate Pecker model, consider the following.
・Applicable Models | ・Model Section Guide | ・Breaking Power |
● APPLICABLE MODELS |
Layout | Tool | STRUCTURE PLAN |
|||||
Type | Breaking Power(t) | ||||||
5.5 | 9 | 14 | 27 | 40 | |||
Waist Level | Standard | GP-MN | GP-DM | GP-5VS | No.1 | ||
Flexible | GP-DF | GP-5FK | GP-10S | No.2 | |||
Floor Level | GP-10F | GP-20F | No.3 | ||||
Standard | GP-5LV | GP-10M | GP-20 | No.4 |
1) | STRUCTURE PLAN | : | For an overview, see STRUCTURE PLAN (PDF*)No.1,No.2,No.3, and No.4. |
* | To view the STRUCTURE PLAN, you need Adobe Reader installed. If you do not have Adobe Reader installed, please download it by Left Button (free of charge). |
● MODEL SECTION GUIDE |
In model selection, narrow it down to the most suitable model while considering the following conditions. |
1. | Casting Material | : | (Tensile strength ㎏/㎜²) | ||||
2. | Sectional Area of Gate | : | ㎜× | ㎜ | |||
3. | Weight | : | Weight in isolation | ㎏/piece | |||
4. | Uses | : | ①Separating Gate | ②Separating Runner | ③Separating Side Riser | ④Separating Top Riser | |
5. | Molding Machine | : | |||||
6. | Frequency of use | : | ①8 Hours/Day | ②16 Hours/Day | ③Other | ||
7. | Layout | : | ①Floor Level Line | ②Waist Level Line | |||
8. | Operation | : | ①Before shot | ②After shot | |||
9. | Voltage | : | V | Hz |
● BREAKING POWER |
The Gate Pecker's breaking power varies greatly with the conditions specified in the casting plan and other plans. For Material FCD-450, refer to the following guide. |
Model | Breaking Power Ton |
Maximum Breakable Sectional Area ㎜² (㎜×㎜) |
GP-MN | 5.5 | 100 (10×10) |
GP-DM(DF) | 9 | 200 (15×15) |
GP-5LV(5VS,5FK) | 14 | 440 (21×21) |
GP-10M(10F,10S) | 27 | 1,100 (33×33) |
GP-20(20F) | 40 | 3,000 (55×55) |
For gate separation with the Gate Pecker, it is extremely important to use the following effectively | |
1)Distance between the bill and breaking point. | |
2)Separator notch. | |
To separate work of Material FCD-450 with a GP-10M, for example, the breaking power with tensile strength alone will be | |
1,100㎜²×45㎏/㎜²=49,500㎏<49.5ton> | |
Even if the friction coefficient is excluded, the GP-10M with a breaking power of 27 ton cannot complete the separation. The key point in this case is therefore to make effective use of 1) and 2). | |
<NOTE> | If there are two or more gates, be sure to begin with the edge of side A in the separation, then process the remaining gates in order. |
1) | CASTING PLAN | : | For an overview, see CASTING PLAN(PDF*). |
* | To view the CASTING PLAN, you need Adobe Reader installed. If you do not have Adobe Reader installed, please download it by Left Button (free of charge). |